服务热线:
18971017202
您的位置:首页 >> 新闻中心

Sb2O3 Masterbatch for Flame-Retardant EVA/XLPE Solar Cables

发布日期:2026-11-21 05:35:38   浏览量:0

1. Application

Flame-retardant EVA/XLPE (electron-beam or silane crosslinked) photovoltaic cables (PV1-F, H1Z2Z2-K) and DC harnesses, where the insulation must meet both IEC 60332-1 vertical burn and long-term UV/salt-fog resistance.

2. Carrier & Dosing

  • Carrier: EVA (VA 18-28%) or XLPE-compatible low-MFI LLDPE carrier, matched within ±10-15% MFI to the base insulation for uniform dispersion under high-shear cable extrusion.
  • Effective Sb2O3 dose: 3-5 wt% on polymer fraction.
  • Ratio: Cl:Sb ≈ 3:1 with chlorinated paraffin CP-52/70, or Br:Sb ≈ 3:1 with DBDPE / brominated epoxy oligomers, calculated on effective halogen not compound weight.

3. Process Checks

  • Pre-dry 2-4h at 70-80°C when storage >60% RH; keep moisture <0.3% to avoid voiding in crosslinking.
  • Melt ≤200°C (XLPE) / ≤190°C (EVA) plate-out watch on die and crosshead; check screen-pack pressure rise as dispersion proxy.
  • Crosslinking interference: with silane or peroxide cure, monitor MDR t90 shift — reject line if offset >10-15% from baseline.
  • Wire line: consistent 0.3-0.5mm wall, no white specks (fine D50 0.8-1.5µm), good dielectric strength and 7-day water-immersion insulation resistance.

4. Qualification

  • IEC 60332-1 vertical burn + LOI on finished cable (not pellets).
  • 85-105°C/1000h heat aging: ΔE and tensile/elongation retention drop <10% red line.
  • QUV/xenon 500-1000h weathering, cold-bend −20°C, salt-fog per PV cable standard.
  • CoA ≥99.5% purity / moisture <0.3% / D50 0.8-1.5µm / Pb<50ppm / Fe<100ppm / whiteness ΔE<1.
  • Per-lot 200g retained sample 12 months; annual requalification.
在线咨询 联系方式 二维码

服务热线

18971017202