1. Application
Flame-retardant EVA/XLPE (electron-beam or silane crosslinked) photovoltaic cables (PV1-F, H1Z2Z2-K) and DC harnesses, where the insulation must meet both IEC 60332-1 vertical burn and long-term UV/salt-fog resistance.
2. Carrier & Dosing
- Carrier: EVA (VA 18-28%) or XLPE-compatible low-MFI LLDPE carrier, matched within ±10-15% MFI to the base insulation for uniform dispersion under high-shear cable extrusion.
- Effective Sb2O3 dose: 3-5 wt% on polymer fraction.
- Ratio: Cl:Sb ≈ 3:1 with chlorinated paraffin CP-52/70, or Br:Sb ≈ 3:1 with DBDPE / brominated epoxy oligomers, calculated on effective halogen not compound weight.
3. Process Checks
- Pre-dry 2-4h at 70-80°C when storage >60% RH; keep moisture <0.3% to avoid voiding in crosslinking.
- Melt ≤200°C (XLPE) / ≤190°C (EVA) plate-out watch on die and crosshead; check screen-pack pressure rise as dispersion proxy.
- Crosslinking interference: with silane or peroxide cure, monitor MDR t90 shift — reject line if offset >10-15% from baseline.
- Wire line: consistent 0.3-0.5mm wall, no white specks (fine D50 0.8-1.5µm), good dielectric strength and 7-day water-immersion insulation resistance.
4. Qualification
- IEC 60332-1 vertical burn + LOI on finished cable (not pellets).
- 85-105°C/1000h heat aging: ΔE and tensile/elongation retention drop <10% red line.
- QUV/xenon 500-1000h weathering, cold-bend −20°C, salt-fog per PV cable standard.
- CoA ≥99.5% purity / moisture <0.3% / D50 0.8-1.5µm / Pb<50ppm / Fe<100ppm / whiteness ΔE<1.
- Per-lot 200g retained sample 12 months; annual requalification.