服务热线:
18971017202
您的位置:首页 >> 新闻中心

Sb2O3 Masterbatch for Flame-Retardant TPU Cable Jacketing & Flexible Sheathing

发布日期:2026-11-21 05:27:30   浏览量:0

1. Why Masterbatch Over Raw Powder in TPU

Thermoplastic polyurethane (TPU) is the workhorse for halogenated flame-retardant (FR) cable jacketing, flexible conduits and hoses where oil resistance, abrasion and low-temperature flexibility matter. Using a pre-compounded Sb2O3 masterbatch instead of dosing raw antimony trioxide powder into the twin-screw line delivers four compounding-critical gains: - Dust-free, non-lung-irritant handling — critical on TPU lines run at high screw speeds where raw powder blows off the feeder. - Accurate dosing at low add-on — effective Sb2O3 is only ~3–5 phr; a 1:1 or 1:2 let-down masterbatch meters it far more repeatably than a micro-doser on raw powder. - Consistent dispersion & batch-to-batch color — TPU is translucent and even slight Sb2O3 clumping shows as white specks; a masterbatch disperses the oxide and carrier uniformly. - Thermal stability window matched — TPU melt runs 190–225 °C; the masterbatch carrier must be stable in that window and not hydrolyze.

2. Carrier Selection & MFI Matching

  • Choose a carrier with TPU-compatible rheology. Polyether-TPU, polycaprolactone (PCL) or high-flow EVA (MFI 10–30) are typical; avoid excessive plasticizer migration that softens the jacket.
  • Match carrier melt flow to the base TPU grade so the masterbatch pellets melt and distribute homogeneously at the machine temperature — target MFI within ±10–15% of the base resin at the operating set-point.
  • Confirm carrier is halogen-free and does not add incompatible plasticizers that shift Shore hardness or migration.

3. FR Formulation & Synergist Ratio

  • Halogenated FR package: use brominated (brominated epoxy, brominated polystyrene or tetrabromobisphenol-A derivatives) or chlorinated (CP-52/70) compounds at a bromine-to-antimony (Br:Sb) ≈ 3:1 or chlorine-to-antimony (Cl:Sb) ≈ 3:1 molar ratio, computed on effective halogen (not nominal additive weight) for maximum synergism.
  • Effective Sb2O3 add-on: 3–5 phr (≈2.5–4 wt%); take the low end for thin-wall or low-gloss jackets where impact and flexibility must be preserved.
  • Optional smoke suppression: zinc borate at 30–50% of the Sb2O3 level to cut smoke density and afterglow in confined cable runs.
  • Always verify the final UL 94 / IEC 60695 rating on the actual wall thickness and construction, not on a thick lab plaque.

4. Dispersion, Drying & Processing Windows

  • Dispersion QC: monitor screen-pack pressure rise, screw torque and die/screw-plate-out. Rising screen delta signals under-dispersion; stop and re-check let-down ratio.
  • Drying: TPU and PCL carriers are hygroscopic — pre-dry masterbatch pellets 2–4 h at 75–85 °C to moisture <0.3% before use; keep the base TPU dried to <0.02% to prevent hydrolysis-driven viscosity drift and bubble/silver-streak defects.
  • Melt temperature: keep ≤ 225 °C to limit antimony oxide color shift and TPU degradation; run the barrel profile to a smooth melt with no unmelted carrier streaks.
  • Check gel content / extrusion appearance on the jacket for white specks and blooming, especially on dark or translucent colored cables.

5. End-Product Verification

  • Flammability: UL 94 V-0/V-1 or IEC 60695-11-10 on the finished jacket wall thickness; for cable use confirm flame-retardant cable standards (e.g. IEC 60332-1/3, VDE 0472) relevant to the target market.
  • Mechanical retention: tensile strength and elongation-at-break retention ≥ 85% vs. the non-FR reference; confirm Shore hardness within spec.
  • Low-temperature flexibility: pass cold bend/cold impact at −20 °C (e.g. IEC 60811 low-temperature tests) with no cracking.
  • Aging: 85–105 °C thermal aging with no exudation, blooming or Sb2O3 migration; for oil-exposed applications confirm oil-resistance retention.
  • Electrical: dielectric strength and surface/volume resistivity within cable spec.

6. CoA Requirements (as received)

  • Sb2O3 content ≥ 99.5%, moisture < 0.3%, Pb < 50 ppm, Fe < 100 ppm, D50 0.8–1.5 µm, whiteness ΔE < 1.
  • Carrier type + MFI statement on the CoA so the let-down ratio is traceable.
  • 200 g retained sample per batch, kept 12 months.

7. Traceability

  • Batch number ↔ CoA ↔ retained sample ↔ TPU cable production lot traceability for ≥ 5 years; annual re-qualification of the masterbatch and re-certification if the carrier is changed without notice (no silent carrier swaps).
在线咨询 联系方式 二维码

服务热线

18971017202

扫一扫,关注我们