服务热线:
18971017202
您的位置:首页 >> 新闻中心

Sb2O3 Masterbatch for Rigid PVC Electrical conduit — dosing vs. wall thickness

发布日期:2026-11-21 05:35:53   浏览量:0

Application: Rigid PVC conduit (EN 61386 / UL 514B class) & cable trunking profiles.

Carrier & dosing: rigid-PVC K-value 58–65 or EVA-CPE carrier matching the compound. Effective Sb2O3 3–5 phr on the PVC fraction. Wall thickness governs dose: ≥1.5 mm walls reach FR class at 3 phr; thin-wall 0.8–1.0 mm conduit typically needs 4–5 phr. Cl:Sb ≈ 3:1 maintained with chlorinated paraffin CP-52/70 co-additive.

Processing: twin-screw/twin-strut extrusion melt ≤190°C; fine-grade D50 0.8–1.5 µm prevents calibration-sleeve plate-out and die lip build-up on high-speed trunking lines.

QC: per-lot CoA — purity ≥99.5%, moisture <0.3%, D50 0.8–1.5 µm, Pb <50 ppm, Fe <100 ppm, whiteness ΔE<1. End-product checks: impact (drop test per EN 61386), Vicat softening <10% drop vs. unfilled control, dielectric resistance, reaction-to-fire at final wall thickness.

Trial & records: bench two-roll heat-stability (torque drop <15% red line) before scale-up; 200 g retained sample per lot, 12 months; annual requalification.