1. Why masterbatch over raw powder for large white-goods liners
Large ABS refrigerator / washing-machine liners are thermoformed and vacuum-formed from 0.8–2.0 mm sheets. Switching from loose Sb2O3 powder to a carrier masterbatch delivers three measurable gains:
- No powder dust at the compounding hopper — safer (occupational exposure) and cleaner feeding on high-throughput sheet lines.
- Consistent per-kilogram dosing — a powder batch can segregate during transport; a masterbatch holds the effective Sb2O3 within ±0.2 wt% across the whole lot.
- Better dispersion before thermoforming — fewer agglomerates means fewer white specks and pinholes on the glossy liner skin after vacuum forming.
2. Dose window and halogen-antimony balance
- Target effective Sb2O3 3–5 phr on the ABS compound; below 3 phr you lose UL94 margin, above 5 phr you start to see haze and surface bloom on glossy liners.
- Pair with a brominated flame retardant at Br:Sb ≈ 3:1 calculated on effective bromine (not on the compound weight of the brominated additive). For ABS the common pairing is tetrabromobisphenol-A (TBBPA) / brominated epoxy oligomer; retune to the halogen source actually used.
- If the liner contains recycled ABS, re-verify the ratio against the actual bromine content of the regrind — a fixed phr ratio assumes a constant bromine source.
3. Carrier selection and process discipline
- Use a styrenic carrier (ABS/SAN) with an MFI within 10–15 % of the liner resin so the masterbatch disperses in the shear zone without creating streaks.
- Pre-dry the ABS resin < 0.02 % moisture (typically 80–90 °C, 2–4 h) to avoid splay/silvering during sheet extrusion — hydrolysis is the classic cause of cosmetic rejects on glossy liners.
- Keep melt temperature ≤ 220 °C; higher temperature increases Sb2O3-induced yellowing risk on white/cream liners.
4. Thin-wall warpage and dimensional QC
- Large thin-wall parts are warpage-sensitive. Confirm the masterbatch does not shift the UL94 rating at finished wall thickness (e.g. 1.0 mm ribbed vs 1.6 mm flat) — always certify on the final part, not on a thick plaque.
- Sample checks per lot: UL94 V-0 at finished wall, glossy-surface haze ΔE < 1 vs. standard, cold-crack / impact retention ≥ 85 % vs. non-flame-retardant control, and 70–105 °C heat-age with no surface bloom.
- Take 200 g retained sample per lot and keep batch number ↔ CoA ↔ finished-part traceability for ≥ 5 years.
5. What to ask the supplier (CoA checks)
Purity ≥ 99.5 %, moisture < 0.3 %, D50 0.8–1.5 µm, Pb < 50 ppm, Fe < 100 ppm, whiteness ΔE < 1, with a per-lot CoA and one-line trial record. Annual requalification recommended.