Why Masterbatch Over Powder for Clarity-Grade Sheet

For clear rigid PVC sheet (packaging blisters, display trays, forming-grade liner sheet), ground Sb₂O₃ powder is a clarity risk: fines agglomerate into visible white specks, dust contaminates the melt, and batch-to-batch dosing drifts. A masterbatch fixes all three—clean dosing, pre-dispersed pigment, lot-consistent loading—so the end sheet stays haze-free.

Carrier & Dosing Guidelines

  • Carrier match: rigid-PVC grades K55–K60 or an EVA/CPE carrier of matching polarity and MFI (±10–15%) so it fluxes uniformly in the dry-blend; a mismatched carrier leaves resin-rich streaks in clear sheet.
  • Effective dose: 2.5–4 wt% effective Sb₂O₃ (flame-retardant clarity sheet) or 3–5 phr in the sheet formulation. Keep dose at the low end—higher loading pushes haze up.
  • Halogen synergy: Cl:Sb ≈ 3:1 with CP-52/70, or Br:Sb ≈ 3:1 retuned on effective halogen weight (not compound weight). For transparency keep the brominated FR option light; CP on a clarity sheet may tint.
  • Calcium/zinc stabilizer balance: Sb₂O₃ interacts with the Ca/Zn package—confirm heat stability (two-roll/torque, ≤10–15% torque drop red line) and plate-out watch on the forming rolls.

Process & QC Checks

  • Pre-dry: 2–4 h at 80°C when storage has been >60% RH—moisture degrades clarity (hydrolysis haze) and feeds silver-streak voids on the calender/forming line.
  • Melt window: ≤185–190°C. Overheat drives plate-out on calender rolls and die lips, which then reads as sheet surface bloom.
  • Trial before commit: verify haze <2–3% and transmittance ≥85% on a trial sheet before batch commitment; check sheet gloss, thermoform sag consistency, and no white specks at high forming rate.

CoA Qualification (per lot)

  • Purity ≥99.5%, moisture <0.3%, D50 0.8–1.5 µm, Pb <50 ppm, Fe <100 ppm, whiteness ΔE<1 per lot.
  • 200 g per-lot retained sample kept 12 months; lot ↔ CoA ↔ finished-sheet traceability ≥5 years; annual requalification.
  • Final-part reaction-to-fire (UL94 V-0 / EN 13501-1) verified on the thermoformed tray wall thickness, not an unfilled plaque.