Application Context
Heat-shrinkable polyolefin (PO) tubing — used for wire/cable termination, busbar insulation and battery pack covers — must pass flame-retardant ratings on the finished shrunk wall, not on the raw extrusion wall. Switching from antimony trioxide (Sb2O3) powder to a masterbatch improves dust-free handling, metered dosing and dispersion uniformity, which matters when the tube is crosslinked (radiation/chemical) before shrinking.
Masterbatch Design Points
- Carrier match: use a high-flow polyolefin carrier (LLDPE/LDPE or EVA, MFI 5–30) matched to the base PO within ±10–15%. Avoid carrier incompatibility that shifts shrink temperature or gel content.
- Effective Sb2O3 dosing: 3–5 phr of Sb2O3 on the polymer fraction, with Br:Sb ≈ 3:1 (molar) calculated on effective bromine, not compound weight. Add zinc borate 30–50% of Sb2O3 for low-smoke synergy where smoke density (NFF16-101 / ASTM E662) is specified.
- Fine grade D50 0.8–1.5 µm: prevents white specks/bloom on the translucent heat-shrink surface and avoids localized dose spikes that cause uneven flame performance.
- Pre-dry masterbatch 2–4 h at 70–80 °C if stored >60% RH; keep moisture <0.3% to prevent voids in crosslinked sections.
- Crosslinking & shrink-back checks: monitor gel content (peroxide/EB crosslink consistency) and radial shrink ratio; verify tube does not bloom or surface-separate after shrink at rated temperature (typically ≤150–175 °C).
Process & Finished-Part QC
- Melt temperature ≤230 °C; watch die plate-out and screen-pack pressure rise as dispersion proxies.
- Final rating on shrunk tube: UL94 V-0 / VW-1 (or IEC 60695) at the actual shrunk wall thickness, plus a cold-bend at −20 °C and heat-age at 85–105 °C with no surface exudation.
- Confirm dielectric and surface resistivity if the tubing carries rated voltage.
CoA & Traceability (buyer checklist)
- Purity ≥99.5%, moisture <0.3%, D50 0.8–1.5 µm, Pb <50 ppm, Fe <100 ppm, whiteness ΔE <1, plus a declared carrier MFI.
- 200 g per-lot retained sample for 12 months; keep lot ↔ CoA ↔ retained-sample ↔ shrink-line-trial traceability ≥5 years with annual re-qualification. Any carrier change requires re-qualification, not silent substitution.