Application Context
PVC cable conduit, flexible trunking, and electrical tubing require flame retardancy with dimensional stability. Antimony trioxide (Sb2O3) masterbatch delivers uniform dispersion while avoiding powder dusting and batch inconsistency.
Masterbatch vs Powder — Why Masterbatch
- Dust-free handling, no airborne exposure at dosing
- Lot-to-lot consistency via pre-dispersed carrier
- Reduced plate-out / surface bloom in thin-wall extrusion
- More predictable dose ladder for UL94 V-0/V-2 at final wall thickness
Carrier Selection
- Rigid PVC conduit: match carrier K-value 58–65 (rigid-PVC carrier) or EVA/CPE for polarity compatibility
- Flexible trunking: flexible-PVC carrier with declared plasticizer (DINP/DOA) content
- Verify carrier MFI/polarity against the base resin to avoid segregation at the screw
Dosing & Halogen-Antimony Ratio
- Typical dose: 3–5 phr Sb2O3 (as masterbatch loading)
- Chlorinated paraffin CP-52/70 halogen source: Cl:Sb ≈ 3:1 molar
- If a brominated FR is co-used, retune to Br:Sb ≈ 3:1 (calculated on effective bromine, not compound weight)
- With zinc borate co-additive for smoke suppression, hold 30–50% of the Sb2O3 position
Processing Checks
- Melt temperature ≤ 190 °C; monitor die / calibration plate-out and surface whitening
- Pre-dry 2–4 h at 80 °C when storage RH > 60% to prevent hydrolysis-driven specks
- Two-roll dispersion check + filter-pack pressure rise as a dispersion proxy per lot
- Ca-Zn stabilizer balance: Sb2O3 can interact with the stabilizer package — verify heat stability
QC / Qualification
- CoA per lot: purity ≥ 99.5%, moisture < 0.3%, Pb < 50 ppm, Fe < 100 ppm, D50 0.8–1.5 µm, whiteness ≥ 96
- Reaction-to-fire rating at target wall thickness (EN 13501-1 / UL94)
- End-product: cold-bend, dielectric strength, surface resistivity, heat-aging
- Retain 200 g per lot for 12 months
Supplier Qualification Checklist
- Documented D50/D97 and antimony content per batch
- Pb/Fe/moisture declared and testable on CoA
- Whiteness consistency across lots (visual + ΔE < 1)
- Line-trial qualification before batch commit