Application Context
PVC medical tubing (IV lines, catheters) and blood-bag films need flame retardancy without compromising clarity, flexibility, and biocompatibility. Sb2O3 masterbatch lets the processor dose a consistent fine-grade antimony with minimal dust exposure and batch-to-batch variation.
Dosing & Carrier Selection
- Carrier: flexible PVC grade (K-value 60-70) with declared plasticizer (DINP/DEHT preferred, medical-adjacent) matching the target resin polarity.
- Dose: 3–5 phr effective Sb2O3 (Cl:Sb ≈ 3:1 with chlorinated paraffin CP-52/70, or Br:Sb ≈ 3:1 on effective bromine from brominated FRs). Adjust down for thinner films that must stay clear.
- Fine grade: D50 0.8–1.5 µm, low Pb/Fe to avoid haze, specks, or bloom on translucent tubing.
Processing & QC Checks
- Pre-dry 2–4 h at 70–80 °C when storage RH >60% to prevent moisture-driven haze/silver streaks.
- Melt ≤ 190 °C; watch die/calibration plate-out on thin-wall profiles.
- Per-lot trial: haze/transmittance on film, cold-bend −20 °C, and LOI/vertical-burn on finished tubing (not raw compound).
- Biocompatibility: verify no heavy-metal migration; request a no-silicone/low-additive declaration if the end use is invasive.
CoA Verification Checklist
- Purity ≥99.5% · Moisture <0.3% · D50 0.8–1.5 µm · Pb <50 ppm · Fe <100 ppm · Whiteness consistent (ΔE <1)
- 200 g per-lot retained sample, 12 months.
Supplier Qualification
Confirm medical-grade supply history, migration-test support, and an audit trail from raw antimony lot to shipped masterbatch (lot traceability).