服务热线:
18971017202
您的位置:首页 >> 新闻中心

Sb2O3 Masterbatch for Flexible PVC Roofing Membranes & Waterproofing Sheets

发布日期:2026-11-21 05:35:31   浏览量:0

1. Application Context

Flexible PVC single-ply roofing membranes and waterproofing sheets must meet reaction-to-fire ratings while surviving years of UV, heat, and cold flexing outdoors. Sb2O3 is the standard halogen-antimony synergist in these plastisol/calendered PVC constructions.

2. Masterbatch vs Powder — Why Masterbatch Wins

  • Clean dosing: powder causes dusting and weighing drift; masterbatch delivers exact effective Sb2O3 per batch.
  • Finer dispersion: pre-dispersed fine-grade (D50 0.8–1.5µm) avoids white specks and bloom on dark membranes.
  • Lot consistency: fixed carrier composition makes flame-retardant performance reproducible membrane-to-membrane.

3. Formulation Parameters

  • Carrier: flexible-PVC carrier (K-value 60–70) with declared plasticizer level (DINP/DOA), or EVA/CPE carrier for polarity match.
  • Dose: 3–5 wt% effective Sb2O3 on polymer fraction.
  • Halogen ratio: Cl:Sb ≈ 3:1 with chlorinated paraffin CP-52/70; retune to Br:Sb ≈ 3:1 on effective bromine if brominated FRs are used.
  • Optional smoke suppression: zinc borate 30–50% of Sb2O3 loading to cut smoke density in fire tests.

4. Key Processing & QC Checks

  • Pre-dry: 2–4 h at 70–80 °C when storage RH > 60% to prevent moisture-driven surface bloom.
  • Melt temperature: keep ≤ 190 °C; watch die/calender plate-out and weld-line formation.
  • Weld seam strength: seam peel/overlap weld must retain ≥ 90% strength vs. unwelded sheet (drop < 10%).
  • Cold flex: −20 °C cold-bend test on finished sheet per lot.
  • Weathering: QUV/xenon 500–1000 h ΔE < 2.0 and no bloom re-emergence; 22 h/70 °C plasticizer-migration bloom check.
  • Fire rating: reaction-to-fire class at target membrane thickness (e.g., EN 13501-1 / ASTM E84); LOI on finished sheet, not raw powder.

5. CoA Verification per Lot

Purity ≥ 99.5% | moisture < 0.3% | D50 0.8–1.5µm | Pb < 50 ppm | Fe < 100 ppm | whiteness ΔE < 1.

6. Supplier Qualification & Traceability

  • Request per-lot CoA with batch number traceable to retained sample (200 g, 12 months).
  • Annual requalification: confirm carrier consistency and flame-retardant performance on field-aged samples.
  • Run a trial membrane (calender or extrusion line) before batch commitment; check gloss, weld strength, and UV retention.