Application context
Corrugated flexible/rigid PVC conduit (波纹管) and cable trunking ducts are extruded from plasticised or rigid PVC at high line speed. They must meet reaction-to-fire ratings (EN 61386, GB/T 20041 series, UL 94) while keeping wall uniformity and flexural integrity during corrugation.
Masterbatch-over-powder rationale
- Dust-free dosing and lot consistency on high-speed corrugation lines (powder side-streams cause feeding drift and batch-to-batch Sb2O3 variance).
- Cleaner dispersion avoids white specks / un-melted agglomerates that crack during corrugation pinching.
- Pre-dispersed carrier reduces plate-out on the corrugating mandrel, extending run length between cleanouts.
Carrier selection
- Rigid conduit: rigid-PVC carrier, K-value 58–65, matched to the base resin for homogeneity.
- Flexible conduit: flexible-PVC carrier with declared plasticiser content (DINP/DOA) and EVA/CPE compatibiliser where needed.
- Confirm carrier MFI/polarity match; a mismatch shifts viscosity and can destabilise the corrugation process.
Dose and synergy window
- Effective Sb2O3 dose: 3–5 phr (rigid) or 4–6 phr (flexible), balanced against cost and mechanical retention.
- Halogen–antimony ratio: Cl:Sb ≈ 3:1 with chlorinated paraffin CP-52/70, or Br:Sb ≈ 3:1 retuned on effective bromine when using brominated flame retardants.
- Optional zinc borate (30–50% of Sb2O3) for smoke suppression in cable-trunking applications.
Processing & QC
- Pre-dry masterbatch 2–4 h at 70–80 °C when storage humidity >60% RH.
- Melt temperature ≤190 °C; watch die and corrugating-mandrel plate-out (pressure-rise proxy).
- Per-lot QC: LOI / vertical-burn per EN 61386 or UL 94 on finished wall thickness; cold-bend −20 °C; dielectric strength for trunking; flexural/impact retention <10% drop versus base.
- Two-roll dispersion check before line trial; screen-pack pressure monitoring.
CoA verification
- Purity ≥99.5%, moisture <0.3%, D50 0.8–1.5 µm, Pb <50 ppm, Fe <100 ppm, whiteness ΔE<1 per lot.
- Keep 200 g retained sample per lot for 12 months; annual requalification.
Selection advice: for corrugated conduit and trunking, masterbatch improves run consistency and flame-performance reliability. Match carrier to the base resin, retune the halogen ratio, and qualify on finished conduit wall, not pellets.