服务热线:
18971017202
您的位置:首页 >> 新闻中心

Sb2O3 Masterbatch for PTFE & Fluoropolymer Wire Insulation

发布日期:2026-11-21 05:35:36   浏览量:0

Application Context

PTFE/fluoropolymer (FEP/PFA) wire insulation and coax-jacket compounds need flame retardancy at high service temperatures (180–260°C). Sb2O3 masterbatch lets a fluoropolymer processor dose the synergist cleanly into a melt-processable fluoropolymer (FEP, PFA, ETFE) without handling loose antimony dust or fighting dispersion in a very high-viscosity, high-melt-temperature system.

Masterbatch-over-Powder Rationale

  • Clean dosing: antimony content is pre-compounded into a fluoropolymer-compatible carrier, avoiding dust exposure and weighing errors at the extruder.
  • Dispersion: a high-shear twin-screw concentrates the fine Sb2O3, so the thin wire-wall (0.1–0.5 mm) shows no white specks or surface bloom.
  • Lot consistency: batch-to-batch antimony content, whiteness and moisture are locked in the masterbatch, key for UL/IEC rating stability.

Carrier & Halogen–Antimony Ratio

  • Use a carrier matched to the base fluoropolymer polarity and melt index (FEP vs ETFE vs PFA carriers are NOT interchangeable).
  • Maintain ≈3:1 halogen:antimony by effective halogen on the polymer fraction. With brominated FRs (e.g. DBDPE, brominated polystyrene) retune to Br:Sb≈3:1; the antimony dose is calculated on the resin phase, not on total compound weight.

Dosing & Processing Window

  • Effective Sb2O3 dose typically 3–5 wt% on the polymer fraction; confirm the UL94 V-0 / IEC 60332-1 rating at the actual insulation wall thickness.
  • Fluoropolymers process at 300–380°C; the brominated synergist must be thermally stable in that window, and the masterbatch carrier must not decompose or release corrosive gas.
  • Watch for die and sizing plate-out on the fine wire crosshead; a coarse/fine D50 balance prevents both specking and settling in the hopper.

Quality / CoA Verification

  • CoA per lot: purity ≥99.5%, moisture <0.3%, D50 0.8–1.5 µm, Pb <50 ppm, Fe <100 ppm, whiteness ΔE <1.
  • Run a trial extrusion and check: dielectric strength, spark continuity, adhesion/peel on the insulated wire, and the final UL94/IEC fire rating on finished wire (not raw pellets).
  • Retain a 200 g per-lot sample for 12 months and require annual re-qualification, since fluoropolymer grades change and fire standards get re-issued.

Supplier Checks

  • Confirm the masterbatch carrier is fluoropolymer-compatible and certified for the target wire spec (automotive, aerospace, or appliance wiring).
  • Verify the CoA batch number ties to the certificate and to your retained sample for full lot traceability.
在线咨询 联系方式 二维码