Application Context
Biaxially oriented PET (BOPET) films are used in electrical insulation, cable wrapping, and capacitor dielectric layers where flame retardancy must be achieved without sacrificing optical clarity or surface quality. Metallized film adds a vacuum-deposited aluminum layer, imposing strict limits on outgassing and surface defects.
Masterbatch vs. Powder — Why a Carrier
- Fine Sb2O3 powder (D50 0.8–1.5 µm) blends into PET poorly without a matching carrier; powder raises haze, creates agglomerate streaks, and causes uneven fire performance.
- A PET-compatible masterbatch with declared intrinsic viscosity (IV 0.55–0.72 dL/g) matches the base resin rheology, disperses uniformly, and keeps the web haze low.
Dosing & Synergy
- Effective Sb2O3 dose: 2.5–4 wt% on polymer fraction for UL94 V-0 / VTM-0 at the final film gauge.
- Br:Sb ≈ 3:1 molar ratio, retuned on effective bromine when using brominated aromatic co-additives (e.g., brominated epoxy oligomers) compatible with PET processing.
Key Process Checks
- Pre-dry PET resin to <0.005% moisture before extrusion to avoid hydrolysis-driven IV loss and haze.
- Melt window: keep ≤265°C; watch die and chill-roll plate-out (white buildup) across a production run.
- Dispersion proxy: screen-pack pressure rise and die-pressure stability; film streaks and specks are the rejection signals.
- Metallized film: confirm no outgassing/volatile residues that would degrade vacuum metallization adhesion.
Final-Product QC (not on raw pellets)
- LOI / vertical-burn on the finished film/web.
- Haze <2–3% and transmittance targets on clear grades; ΔE whiteness consistency across lots.
- Dielectric strength and adhesion after metallization where applicable.
CoA Verification (per lot)
Purity ≥99.5%; moisture <0.3%; D50 0.8–1.5 µm; Pb <50 ppm; Fe <100 ppm; whiteness ΔE <1; batch number ↔ retained sample (200 g, 12 months).
Supplier Qualification
Medical/electrical-grade traceability, per-lot CoA linked to batch number, annual requalification, and line-trial qualification before committing volume.