服务热线:
18971017202
您的位置:首页 >> 新闻中心

Sb2O3 Masterbatch for Moisture-Cure Polyurethane Sealants & Cast Elastomers

发布日期:2026-11-21 05:35:40   浏览量:0

1. Why masterbatch over powder

  • Dispersion without moisture ingress: powder Sb2O3 carries surface moisture & agglomerates that can seed NCO-water side reactions; a PU-compatible masterbatch disperses dry and keeps effective dose consistent lot to lot.
  • Clean dosing on single-component lines: isocyanate prepolymers are moisture-sensitive; a closed masterbatch feed avoids dust, ambient humidity pickup, and weigh errors on 1-K dispensing equipment.
  • Lot consistency for CoA compliance: masterbatch holds antimony content, whiteness ΔE<1, and D50 within tighter band than hand-added powder.

2. Carrier selection (critical)

  • Polyol carrier (polyether/polyester diol) preferred: dissolves into the polyol side, no inert polymer islands, no viscosity shock.
  • Avoid amine/mercaptan or water-carrier resins — they consume isocyanate or release gas.
  • Declare OH value, moisture <0.1%, and NCO-free status in the masterbatch CoA.

3. Dosing & synergy

  • Effective Sb2O3 3–5 wt% of the total sealant/elastomer formula.
  • Pair with a brominated flame retardant (e.g. brominated epoxy oligomer, DBDPE) at Br:Sb ≈ 3:1 molar on effective bromine for UL94 V-0 or EN 13501-1.
  • Optional zinc borate 30–50% of the Sb2O3 dose for smoke suppression in fire-rated joints.

4. Cure-interference watch (the key QC)

  • Run a tack-free / full-cure time test on a masterbatch-loaded batch vs a powder baseline; reject if cure time shifts >10–15%.
  • Check gel/tack-free time, through-cure thickness, and 7-day hardness (Shore A/D) before production release.
  • Watch for surface skinning vs core tack mismatch — a sign of moisture or carrier incompatibility.

5. Processing checks

  • Pre-dry masterbatch 2–4 h at 70–80 °C only when storage >60% RH; over-drying of moisture-cure systems not needed.
  • Disperse on a high-shear dissolver/planetary mixer; verify no Sb2O3 sediment in storage (shelf stability ≥6 months without hard settling).
  • Confirm final-part flame test (UL94 / LOI / vertical burn) on cured plaques, not on wet mix.

6. CoA hard gates

  • Purity ≥99.5%, moisture <0.3%, Pb<50 ppm, Fe<100 ppm, D50 0.8–1.5 µm, whiteness ΔE<1.
  • Batch ↔ CoA ↔ retained sample (200 g, 12 months) traceability for ≥5 years.

7. Supplier qualification

  • Verify masterbatch carrier is isocyanate-compatible and free of moisture initiators; request per-lot CoA and line-trial certificate.
  • Requalify annually and on any carrier or resin change.