服务热线:
18971017202
您的位置:首页 >> 新闻中心

Sb2O3 Masterbatch for Crosslinked PE (XLPE) Medium-Voltage Cable Insulation

发布日期:2026-11-21 05:35:42   浏览量:0

Application context: Medium-voltage (MV) XLPE cable insulation runs at elevated conductor temperatures (90°C continuous, 250°C short-circuit) and must hold dielectric integrity while meeting IEC 60332-1 / EN 13501-1 reaction-to-fire on the finished cable, not on the raw compound.

Masterbatch vs. dry-powder dosing

  • Use a masterbatch when cleanliness and lot-to-lot consistency matter: direct powder feeds on a dry-blend line raise speck/contamination risk that becomes a voltage-withstand defect in MV insulation.
  • The carrier must be crosslink-compatible: a low-peroxide-interference LDPE/LLDPE carrier (MFI 2–20, matched within 10–15%) that does not poison the dicumyl peroxide (DCP) crosslinking system.
  • Masterbatch cuts clean dosing at low Sb2O3 levels and keeps the insulation layer free of agglomerates that become tree-initiation sites.

Dosing and synergy

  • Effective Sb2O3 3–5 wt% on the insulation compound, paired with a halogen donor (e.g. brominated compounds or chlorinated paraffin) at ~3:1 halogen:Sb molar ratio, retuned on the effective halogen content.
  • For low-smoke / reduced-toxicity builds, blend 30–50% zinc borate by Sb2O3 weight as a smoke suppressant and char promoter.
  • Because MV insulation is thick-wall and stressed thermally, keep the dose at the lower bound of the window to minimise dielectric loss tangent shift.

Crosslinking interference check (RED LINE)

  • The Sb2O3 masterbatch carrier must not shift cure: run an MDR (moving die rheometer) t90/tc90 check on the compound with and without the masterbatch. A shift >10–15% is a rejection red line — the carrier or additive is interfering with DCP crosslinking.
  • Confirm gel content (ASTM D2765, xylene extraction) stays within spec; insufficient crosslinking degrades long-term water-tree resistance.

Moisture and processing control

  • Pre-dry the masterbatch 2–4 h at 70–80°C when storage humidity >60% RH. Moisture in the insulation layer creates voids that become water-tree and partial-discharge defects.
  • Watch plate-out / die build-up on the extrusion line; any build-up pulls the layer geometry off-spec and invites voiding.

Finished-cable QC (test on cable, not compound)

  • Dielectric strength and 7-day immersion insulation resistance per lot.
  • Reaction-to-fire on finished cable (IEC 60332-1 vertical flame) — the certified result is at cable level.
  • Cold-bend −20°C and heat-aging 135°C/168h with mechanical retention drop <10%.

Supplier qualification (CoA verification)

  • CoA must confirm purity ≥99.5%, moisture <0.3%, D50 0.8–1.5 µm, Pb <50 ppm, Fe <100 ppm, whiteness ΔE <1.
  • Retain 200 g per lot, 12 months; run annual re-qualification with a line-trial on the customer's own extrusion line.
在线咨询 联系方式 二维码

服务热线

18971017202

扫一扫,关注我们