Sb2O3 Masterbatch for PPS (Polyphenylene Sulfide) High-Temperature Electrical & Mechanical Parts
发布日期:2026-11-21 05:35:45 浏览量:0
1. Why Masterbatch Over Powder in PPS
- PPS melts at 280–340°C — most organic brominated synergists decompose before/at this window, so bromine loading must be re-checked at actual processing temperature.
- Powder Sb2O3 in a 300+°C melt risks uneven dispersion → white specks, agglomerates and premature failure in thin-wall electrical parts.
- A masterbatch shields Sb2O3 in a compatible carrier, giving clean dosing, dust-free handling and lot-to-lot consistency at high shear.
2. Carrier & Dispersion
- Use a PPS-compatible carrier (e.g. a low-viscosity PPS or high-temperature engineering-plastic carrier with matching MFI), not a commodity PP/EVA carrier that degrades above ~250°C.
- Two-roll bench dispersion check at 290–310°C before the production moulding trial.
- Filter/flow-pressure proxy: screen-pack pressure rise on the extruder is the practical dispersion gate.
3. Halogen–Antimony Synergy (High-Temperature Retune)
- Br:Sb ≈ 3:1 on effective bromine, not compound weight — re-calculate because high-temperature melt can partially de-brominate synergists.
- Dose: 3–5 wt% effective Sb2O3 on the polymer fraction; reduce 10–15% when switching from powder to masterbatch.
- Confirm the brominated FR's decomposition onset (TGA) is above the processing window; otherwise plate-out and mould fouling follow.
- For low-smoke or UL94 V-0 at thin walls, pair with zinc borate 30–50% of the Sb2O3 loading.
4. Processing & Moisture
- Pre-dry the compound 2–4 h at 80–100°C when storage > 60% RH.
- Melt ≤ 320–330°C for most PPS grades; plate-out watch on the mould/die over 2–4 h.
- Verify UL94 V-0 on finished moulded parts at target wall thickness, not on pellets.
5. CoA & Qualification Checklist
- Purity ≥ 99.5% | Moisture < 0.3% | D50 0.8–1.5 µm | Pb < 50 ppm | Fe < 100 ppm | Whiteness ΔE < 1.
- Per-lot: 200 g retained sample, 12 months; annual re-qualification.
- Trial plaque: tensile/impact retention < 10% drop vs unmodified, heat-ageing at rated service temperature, dielectric (for electrical parts).