服务热线:
18971017202
您的位置:首页 >> 新闻中心

Sb2O3 Masterbatch for PPS (Polyphenylene Sulfide) High-Temperature Electrical & Mechanical Parts

发布日期:2026-11-21 05:35:45   浏览量:0

1. Why Masterbatch Over Powder in PPS

  • PPS melts at 280–340°C — most organic brominated synergists decompose before/at this window, so bromine loading must be re-checked at actual processing temperature.
  • Powder Sb2O3 in a 300+°C melt risks uneven dispersion → white specks, agglomerates and premature failure in thin-wall electrical parts.
  • A masterbatch shields Sb2O3 in a compatible carrier, giving clean dosing, dust-free handling and lot-to-lot consistency at high shear.

2. Carrier & Dispersion

  • Use a PPS-compatible carrier (e.g. a low-viscosity PPS or high-temperature engineering-plastic carrier with matching MFI), not a commodity PP/EVA carrier that degrades above ~250°C.
  • Two-roll bench dispersion check at 290–310°C before the production moulding trial.
  • Filter/flow-pressure proxy: screen-pack pressure rise on the extruder is the practical dispersion gate.

3. Halogen–Antimony Synergy (High-Temperature Retune)

  • Br:Sb ≈ 3:1 on effective bromine, not compound weight — re-calculate because high-temperature melt can partially de-brominate synergists.
  • Dose: 3–5 wt% effective Sb2O3 on the polymer fraction; reduce 10–15% when switching from powder to masterbatch.
  • Confirm the brominated FR's decomposition onset (TGA) is above the processing window; otherwise plate-out and mould fouling follow.
  • For low-smoke or UL94 V-0 at thin walls, pair with zinc borate 30–50% of the Sb2O3 loading.

4. Processing & Moisture

  • Pre-dry the compound 2–4 h at 80–100°C when storage > 60% RH.
  • Melt ≤ 320–330°C for most PPS grades; plate-out watch on the mould/die over 2–4 h.
  • Verify UL94 V-0 on finished moulded parts at target wall thickness, not on pellets.

5. CoA & Qualification Checklist

  • Purity ≥ 99.5% | Moisture < 0.3% | D50 0.8–1.5 µm | Pb < 50 ppm | Fe < 100 ppm | Whiteness ΔE < 1.
  • Per-lot: 200 g retained sample, 12 months; annual re-qualification.
  • Trial plaque: tensile/impact retention < 10% drop vs unmodified, heat-ageing at rated service temperature, dielectric (for electrical parts).