1. Application context
Flame-retardant EPDM/CR/NBR rubber hoses (engine coolant, heater, air, hydraulic return) must meet
UL94 / FMVSS 302 / ISO 6722 and OEM burn requirements while surviving flex, heat aging and fluid
contact. Sb2O3 is added as a halogen-antimony synergist, almost always via masterbatch for clean
metering and even dispersion in the dense rubber matrix.
2. Masterbatch-over-powder advantage
- Cleaner dosing on batch mixing lines; avoids weigh-error and airborne dust in the compound room.
- Pre-dispersed carrier (EPDM/EVA/CR-based masterbatch) shortens the mix cycle and improves
filler distribution — critical where antimony must reach 3–6 phr uniformly through the hose wall.
- Consistent lot-to-lot active content beats raw-powder weigh tolerance.
3. Dose & halogen-antimony ratio
- Effective Sb2O3: 3–6 phr (rubber phr basis), tuned to the halogen source.
- ~3:1 halogen:Sb on effective halogen weight. With chlorinated paraffin (CP-52/70) use Cl:Sb ≈ 3:1;
with brominated systems (DBDPE, TBBPA) retune Br:Sb ≈ 3:1 on effective bromine — not on
compound weight.
- Zinc borate 3–8 phr may be co-added for smoke suppression where hose burn is a rating concern.
4. Dispersion & processing checks
- Two-roll mill dispersion check and Mooney viscosity (ML 1+4) within ±15% of specification.
- Watch bloom/surface exudation on black EPDM hoses — prefer fine-grade D50 0.8–1.5 µm to limit
surface dusting, especially in hot-service hoses.
- Peroxide/sulfur cure interference: confirm t90 shift stays within 10–15% rejection red line when
Sb2O3 masterbatch is added.
5. End-product qualification (on cured hose, not raw compound)
- LOI and vertical burn (UL94 / FMVSS 302 / ISO 6722) on finished hose wall.
- 22h/70°C compression set red line ≤10%; heat aging 135°C/168h with tensile/elongation retention
<10% drop.
- Cold flex −20°C; fluid-resistance soak (coolant/glycol) for wall swell within spec.
6. CoA checks & retained sample
- Purity ≥99.5%, moisture <0.3%, D50 0.8–1.5 µm, Pb<50 ppm, Fe<100 ppm, whiteness ΔE<1 per lot.
- 200 g per-lot retained sample, 12 months; annual requalification.
- Bind CoA lot number ↔ test report ↔ retained sample for ≥5 years traceability.