Application Context

Rigid PVC conduit and trunking require flame retardancy (IEC 61386, LSZH variants) while keeping impact strength and extrusion throughput. Antimony trioxide (Sb2O3) masterbatch pairs with organochlorine sources inherent to PVC or added brominated FRs in non-halogenated compounds.

Formulation Guidance

  • Halogen-to-antimony molar ratio ~3:1; for rigid PVC the resin's chlorine already contributes, so added Sb2O3 typically 3–6 phr depending on wall thickness and required fire rating.
  • Use rigid PVC-compatible carrier (no plasticizer bleed); K-value matched to compound to avoid gel marks.
  • Fine-grade D50 0.8–1.5 µm to avoid rough bore surfaces and plate-out on dies and calibrators.
  • Pre-dry when storage humidity is high; moisture > 0.3% risks voids and surface bloom.

Processing Checks

  • Monitor die pressure and vacuum sizing stability; rising die pressure indicates screen packing from agglomerates.
  • Watch white deposits at the die during long runs — a plate-out indicator; adjust stearate lubricant balance.
  • Impact (fall-weight) and vicat softening must not drop >10% versus control at target dose.

Supplier Qualification (CoA Verification)

  • Purity ≥ 99.5%; Pb < 50 ppm, Fe < 100 ppm; moisture < 0.3%; D50/D97 declared per lot.
  • Whiteness consistency across lots for visible conduit surfaces.
  • Request per-lot retained samples and annual requalification for continuous supply agreements.

Compliance

Confirm RoHS/REACH declarations and construction-product fire classification (EN 13501-1) data for the final conduit system.