服务热线
18971017202
ABS electrical enclosures and electric panel housings demand strict flame-retardant performance together with stable molding quality. Antimony trioxide masterbatch is the standard synergy carrier for this application.
Formulation notes - Pair with brominated epoxy oligomer at Br:Sb ≈ 3:1 — calculated on effective bromine, not compound weight — inside the 240–260 °C melt window where BEO keeps its thermal stability. - Dose around 4–5 wt% Sb2O3 effective for 0.8–1.6 mm wall thickness; retune upward for glass-filled grades, recalculating Br:Sb on the resin fraction only. - Prefer fine D50 0.8–1.5 µm grades for thin-wall housings so parts pass UL94 V-0 without excessive filler that dulls the surface.
Processing / QC - CTI (Comparative Tracking Index) should be verified on molded housing parts near live components — fine grades with clean carriers hold CTI better; confirm on the part, not the pellet. - Monitor plate-out and mold fouling after 2–4 h; rising screen pack pressure means dispersion is degrading. - Electrical insulation checks: dielectric strength and surface resistivity spot-checked on each production lot. - CoA hard checks: purity ≥99.5%, moisture <0.3%, D50/D97 declared, Pb <50 ppm, Fe <100 ppm; reconcile against retained samples per lot.
Qualification & traceability - UL94 V-0/V-1 must be validated on the final product's actual wall thickness — coupon results are not qualification. - 200 g retained sample per lot, 12 months, batch-numbered and linked with the enclosure part run records. - Annual supplier re-audit; any purity or whiteness drift between lots triggers a molding re-trial before release.