Audience: PVC compounding & extrusion engineers sourcing antimony trioxide masterbatch for flexible, reinforced garden hose and braided tubing.
PVC garden hose and reinforced non-kink tubing are twin-extruded braided profiles run in long, continuous lengths on high-speed lines. Your Sb₂O₃ masterbatch has to deliver fire performance required by regional hose specifications without disturbing plastisol or flexible-PVC rheology, printability, or kink resistance.
Formulation and Dosage Notes
- Dose: 3–5 wt% Sb₂O₃ on polymer, calculated to a 3:1 halogen:Sb molar ratio against the chlorine already in PVC plus chlorinated paraffin co-additive (CP-52/70) where used. Overdosing raises hardness and stiffness in thin-wall flexible hose.
- Carrier: flexible PVC or plastisol-compatible carrier; declare plasticizer type and content (DINP/DOA) so it matches the hose compound and keeps Shore A in spec.
- Grade: fine D50 0.8–1.5 µm to avoid white specks and surface bloom on clear/translucent hose, and to survive braiding without grit lines.
- Pre-dry masterbatch stored above 60 % RH before extrusion; moisture drives haze and voids in flexible PVC.
Processing Watchpoints
- Keep melt temperature ≤ 190 °C; Sb₂O₃ can accelerate plate-out on the die and vacuum ports at sustained high temperature, appearing as gray-white deposits that mark the hose surface.
- Monitor die pressure and screen pack; plate-out correlates with rising pressure.
- Braided-braid cover uniformity hides color drift; run a short trial length and check both wall brightness and print adhesion.
Inbound QC and CoA Checks
- Sb₂O₃ purity ≥ 99.5 %; moisture < 0.3 %; Pb < 50 ppm; Fe < 100 ppm.
- D50/D97 particle-size distribution documented per lot, with whiteness consistency for color-critical hose.
- Migration screening for potable-water-contact or drinking-water-adjacent hose where regulations apply.
- EN 13501-1 or local hose fire-class data at the target wall thickness, verified on the finished hose.
Supplier Qualification
Retain a 200 g sample per lot for 12 months and run an annual requalification against the original CoA. For continuous long runs, confirm lot-to-lot whiteness and particle-size consistency before committing the full hose campaign.