Flexible PVC wiring duct and coil tubing need balanced flame retardancy with retained flexibility and surface finish. Halogen (CP) plus Sb2O3 synergy is dosed to meet electrical-appliance fire ratings without embrittling the flexible grade.
Dosing & Formulation
- Dose 4–6 phr Sb2O3 with CP-52/70 at Cl:Sb ≈ 3:1; fine grade D50 0.8–1.5 µm prevents white specks in thin-wall sections.
- Carrier: flexible PVC with declared plasticizer (DINP/DOA) content; match carrier K-value to resin.
- Pre-dry if storage >60% RH to avoid moisture-induced surface bloom.
Process & QC Checks
- Melt ≤190 °C; monitor die/plate-out and gloss consistency on co-extruded surfaces.
- Check flexibility (cold bend), dielectric strength, and flammability rating on finished wall thickness.
- CoA per lot: purity ≥99.5%, moisture <0.3%, Pb <50 ppm, Fe <100 ppm.
Commercial Takeaway
- Masterbatch reduces powder dust and improves feed consistency on flexible extrusion lines.
- Retained sample 200 g per lot for 12 months supports downstream compliance audits.